Equipments
|
Blotter,
Gel
Dryer,
Transilluminator,
Dark
Room,
UV-Cross
linker,
UV
lamps.
|

|
Recommended
power
supply
:
EV3020
|
|
EBS1x00 semi-dry
blotters
offer
rapid
transfer
times
for
DNA,
RNA
and
protein
blotting
(typically
15
to
30
minutes).
Features
-All
units
can
be
used
for
all
types
of
blotting
and
are
compatible
with
gel
thickness
from
0.25
up
to
10
mm
without
the
need
for
additional
equipment.
Each
unit
is
compatible
with
their
respective
vertical
gel
system.
-Semi-dry
blotting
has
the
added
benefit
of
economic
transfers
due
to
very
low
buffer
volumes.
-These
blotters
utilise
a
screw
down
lid,
which
secures
the
blot
sandwich
and
allows
complete
control
of
pressure
ensuring
even
transfer.
-The
electrodes,
comprising
platinum
coated
anode
and
stainless
steel
cathode,
will
exhibit
practically
no
corrosion
and
so provide
many
years
of
trouble
free
use.
-Uniform
heat
dispersion
across
the
blot
sandwich
ensures
stable
transfer
times
and
no
heat
induced
sample
loss
or
transfer distortions.
-Electrode
plates
are
fully
separated
to
prevent
arcing
or
damage.
Ordering
codes
:
EBS1100
Semi-dry
blotter,
mini,
10x10
cm
5
ml
1
blot,
10x10
cm
16x16x7
cm
EBS1200
Semi-dry
blotter,
midi,
20x20
cm
20
ml
1
blot,
20x20
cm
or
4
blots,
10x10
cm
26x26x7
cm
|

|
Recommended
vacuum
pump: KNF
N820.3
FT.40.18
|
|
EDRY1x00
With
a
drying
area
of
21x31
cm,
the
Midi
gel
dryer
can
dry
six
10x10cm
gels
or
a
single
larger
gel.
The
maxi
gel
dryer
with
a
35x45
cm
drying
area
can
dry
twelve
10x10
cm
mini
gels
simultaneously.
Features
-The
unit’s
microprocessor
controls
temperature
and
time,
each
parameter
being
displayed
on
its
own
LED
display.
-The
gels
are
heated
from
the
base
plate
while
the
vacuum
removes
the
moisture
from
below
to
dry
the
gel
homogeneously.
-Features
optimal
sealing
using
a
silicone
rubber
cover
and
supporting
mask.
-When
applying
the
vacuum,
a
groove
that
frames
the
drying
surface
provides
an
optimal
tight
seal
during
the
drying.
Ordering
codes
:
|
dimensions:
|
Drying
area:
|
Timer
|
Temp.
increment
|
Temp.
uniformity
|
EDRY1100
Midi
gel
drye
|
30x26x8
cm
|
21x31
cm
|
1...999
minutes
|
0.1°C
|
0.2°C
|
EDRY1200
Maxi
gel
drye
|
44x50x8
cm
|
35x45
cm
|
|

|

VLS6
Stand
for
VL8,
VL6,
VL4
lamps
VLS30
Stand
for
VL215.
VL115
lamps
|
|
|
The
UV
lamps
are
provided
in
254,
312,
365
nm
or
combined.
The
unique
filter
minimizes
white
light
interference
allowing
you
to
easily
detect
weak
fluorescence.
Features
The
filter
has
unlimited
life
expectancy
for
312
and
365nm
(3000
hours
for
254
nm).
•
Easy
to
handle
•
Single
or
dual
wavelength
•
Long
live
filter
and
high
UV
output
•
Ondulex®
reflector
for
optimum
UV
irradiance
•
Lamp
stand
or
holder
to
add
versatility
Code
|
nm
|
Tubes
|
Intensity(μW/cm2)
|
VL215-L
|
365
|
2x15
W
|
2300
|
VL215-C
|
254
|
2x15
W
|
1780
|
VL215-M
|
312
|
2x15
W
|
3000
|
VL215-LC
|
365/254
|
2x15
W
|
1350/1100
|
VL215-LM
|
365/312
|
2x15
W
|
1350/1800
|
VL215-MC
|
312/254
|
2x15
W
|
1800/930
|
VL115-L
|
365
|
1x15
W
|
1100
|
VL115-C
|
254
|
1x15
W
|
1000
|
VL115-M
|
312
|
1x15
W
|
1000
|
VL8-L
|
365
|
1x8
W
|
800
|
VL8-C
|
254
|
1x8
W
|
820
|
|
Code
|
nm
|
Tubes
|
Intensity(μW/cm2)
|
VL8-M
|
312
|
1x8
W
|
790
|
VL8-LC
|
365/254
|
2x8
W
|
720/520
|
VL8-LM
|
365/312
|
2x8
W
|
720/660
|
VL8-MC
|
312/254
|
2x8
W
|
660/520
|
VL6-L
|
365
|
1x6
W
|
800
|
VL6-C
|
254
|
1x6
W
|
820
|
VL6-LC
|
365/254
|
2x6
W
|
720/520
|
VL4-L
|
365
|
1x4W
|
400
|
VL4-C
|
254
|
1x4
W
|
340
|
VL4-LC
|
365/254
|
2x4
W
|
350/265
|
|
|
|
|
|
|
|
The
Super-Bright
UV
table
is
a
multi-applications
transilluminator
which
works
for
an
extended
range
of
dyes
including
SYBR-Green®,
Ethidium
bromide,
SYBR
Gold
®,
SYBR
Safe®,
Sypro
Orange®,
Sypro
Ruby®,
Gel
Star
®
...
The
innovative
Super-Bright
filter
stops
all
the
visible
light
emitted
by
the
tubes,
making
the
transilluminator
simply
perfect
for
a
large
number
of
applications.
•Invisible
UV
tubes
-
No background
light
•Enhanced
signal
imaging
&
contrast
visualization
of
the
faint
bands
•Adjustable
dual
intensity
selector
(100%-70%)
•Unlimited
filter
life
expectancy
•Adjustable
UV
safety
screen
•Ondulex
®
reflector
for
higher
UV
output
Enchanced
results
As
the
UV
tubes
are
no
more
visible,
the
Super-Bright
improves
dramatically
the
quality
of
gel
visualization
and
documentation.
By
contrast,
your
eyes
can
easily
see
the
very
faint
bands.
The
Super-Bright
excitation
light
is
far-
off
the
sample
fluorescence.
This
ensures
the
total
transmission
of
the
SYBR-Green®
or
ethidium
bromide
signal
if
combined
with
our
unique
F440
camera
filter.
For
SYBR-Green®,
the
signal
is
then
25%
higher
compared
to
a
standard
configuration.
Multi-applications
transilluminator
Code
|
Description
|
nm
|
Filter
(mm)
|
Tubes
|
Intensity
(μW/cm2)
|
VLECX-26M
|
High
/
Low
intensity
|
312
|
210
x
260
|
6
x
8-watt
|
9 000
|
VLETX-26C
|
High
/
Low
intensity
|
312
|
210
x
260
|
6
x
15-watt
|
10
000
|
VLTCP-26LMX
|
High
/
Low
intensity
|
365/312
|
210
x
260
|
6
x
15-watt
|
10
000
|
|
|
The
SKYLIGHT
SUPER-BLUE
is
a
new
technology
ideal
for
Sybr
Safe®,
Gel-Red®,
Sypro
Ruby®,
Gel-Star®,
Sypro
Orange®,
Sybr
Gold®,
Sybr
Green®
I
&
II
and
eGFP®,
amongst
others
Technology
The
SKYLIGHT
SUPER-BLUE
table
is
based
on
the
latest
blue
LED
technology
for
an
unparalleled
light
uniformity.
The
table
incorporates
270
Light
Emitting
Devices
in
an
optimized
array
to
give
consistent
intensity
across
the
table.
This
uniform
light
is
then
filtered
with
a
narrow
excitation
filter
to
obtain
an
excitation
peak
at
470nm
and
to
eliminate
light
interference
on
the
resulting
image.
On
the
surface,
the
protection
glass
allows
you
to
cut
the
gel
without
damaging
the
table.
Advantages
The
new
SKYLIGHT
SUPER-BLUE
transilluminator
eliminates
the
damage
caused
by
UV
light
on
DNA
and
RNA
gels.
It
also
improves
cloning
efficiency
dramatically
by
eliminating
the
effects
of
UV-induced
nicking
or
crosslinking,
often
encountered
during
the
purification
of
DNA
from
gels
for
further
use.
VLECX-20BLUE
SkyLight
technology
200
x200
Led
technology
|

|
•
Stainless
steel
frame
•
Adjustable
UV
safety
screen
•
Ondulex
®
reflector
for
higher
UV
output
|
|
The
ECX
transilluminator
is
both
compact
and
economical
for
laboratories
with
budget
in
mind.
The
fully
adjustable
UV
safety
screen
can
be
positioned
to
suit
the
operator’s
viewing
angle
against
exposure
to
harmful
UV
rays.
The
High/Low
intensity
selection
is
ideal
to
switch
from
short
gel
visualization
to
longer
preparative
work.
•
Unlimited
filter
life
expectancy
for
312
and
365nm
•
Adjustable
dual
intensity
selector
(100%-70%)
Code
|
Description
|
nm
|
Filter
(mm)
|
Tubes
|
Intensity
(μW/cm2)
|
VLECX-15M
|
High
/
Low
intensity
|
312
|
150
x
150
|
4
x
8-watt
|
10
000
|
VLECX-15C
|
High
/
Low
intensity
|
254
|
150
x
150
|
4
x
8-watt
|
7
000
|
VLECX-20M
|
High
/
Low
intensity
|
312
|
200x
200
|
6
x
8-watt
|
10
000
|
VLECX-20C
|
High
/
Low
intensity
|
254
|
200x
200
|
6
x
8-watt
|
7
000
|
VLECX-20L
|
High
/
Low
intensity
|
365
|
200x
200
|
6
x
8-watt
|
7
000
|
VLECX-26M
|
High
/
Low
intensity
|
312
|
210
x
260
|
6
x
8-watt
|
10
000
|
VLECX-26C
|
High
/
Low
intensity
|
254
|
210
x
260
|
6
x
8-watt
|
7
000
|
|

|
•
6
x
15W
UV
tube
•
UV
safety
screen
•
Air
cooling
fan
•
Stainless
steel
frame
•
Adjustable
UV
safety
screen
•
UV
Master
®
technology
|
|
Super
high
signal
The
ETX
15-watt
transilluminator
has
very
high
UV
output
to
obtain
more
signal
compared
to
a
standard
8-watt
transilluminator.
This
model
has
been
specifically
designed
to
meet
demand
for
analytical
and
preparative
DNA
electrophoresis.
The
ETX
model
is
available
in
254nm,
312
nm
and
365nm.
Dual
intensity
selector
(100%-70%)
•
Powerful
UV
output
ideal
for
the
visualisation
of
faint
bands.
•
Adjustable
dual
intensity
selector
(100%-70%)
•
Ondulex
®
reflector
for
higher
UV
output
•
Unlimited
filter
life
expectancy
for
312
and
365nm
Code
|
Description
|
nm
|
Filter
(mm)
|
Tubes
|
Intensity
(μW/cm2)
|
VLETX-20M
|
High
/
Low
intensity
|
312
|
200
x
200
|
6
x
15-watt
|
10600
|
VLETX-20C
|
High
/
Low
intensity
|
254
|
200
x
200
|
6
x
15-watt
|
7800
|
VLETX-20L
|
High
/
Low
intensity
|
365
|
200
x
200
|
6
x
15-watt
|
7000
|
VLETX-26M
|
High
/
Low
intensity
|
312
|
210
x
260
|
6
x
15-watt
|
10600
|
VLETX-26C
|
High
/
Low
intensity
|
254
|
210
x
260
|
6
x
15-watt
|
7800
|
|
|
UV
/
WHITE
LIGHT
TRANSILLUMINATOR
•
Two
models
in
one!
•
The
UV
/
white
light
tables
feature
two
200
x
200
mm
illumination
areas.
•
The
UV
side
is
ideal
for
RNA
and
DNA
visualization.
•
The
white
light
side
can
be
used
for
protein
gels,
autoradiograms
or
microtitration
plates.
Code
|
Description
|
sample
surface
(mm)
|
UV
Tubes
|
LV
Tubes
|
Intensity
(μW/cm2)
|
VLTFP-MWL
|
312nm
/
white
light
|
2x
(200
x
200)
|
6
x
8-watt
|
2
x
8-watt
|
10000
|
VLTFP-CWL
|
254nm
/
white
light
|
2x
(200
x
200)
|
6
x
8-watt
|
2 x
8-watt
|
7000
|
VLTFP-LWL
|
365nm
/
white
light
|
2x
(200
x
200)
|
6
x
8-watt
|
2 x
8-watt
|
7000
|
MULTI-BAND
TRANSILLUMINATOR
•
The
multi-band
transilluminator
accommodates
two
UV
wavelengths
in
one
single
transilluminator.
•
This
versatile
model
is
ideal
for
a
wide
range
of
applications
requiring
different
wavelengths.
It
can
be
used
for
both
visualization
and
documentation..
Code
|
Description
|
sample
surface
(mm)
|
UV
Tubes
|
Intensity
|
VLTCP-20LC
|
365nm
/
254nm–
8-watt
|
200
x
200
|
(6
x
365nm)+(5
x
254nm)
|
7600
/
5200
|
VLTCP-20LM
|
365nm
/
312nm–
8-watt
|
200
x
200
|
(6
x
365nm)+(5
x
312nm)
|
5400
/
6400
|
VLTCP-20MC
|
312nm
/
254nm
–
8-watt
|
200
x
200
|
(6
x
312nm)+(5
x
254nm)
|
8400
/
5200
|
VLTCP-26LC
|
365nm
/
254nm–
8-watt
|
210
x
260
|
(6
x
365nm)+(5
x
254nm)
|
5400
/
5200
|
VLTCP-26LM
|
365nm
/
312nm–
8-watt
|
210
x
260
|
(6
x
365nm)+(5
x
312nm)
|
7600
/
6400
|
VLTCP-26MC
|
312nm
/
254nm –
8-watt
|
210
x
260
|
(6
x
312nm)+(5
x
254nm)
|
8500
/
5200
|
|
|
The
CN-15
darkroom
provides
a
large
effective
capacity
and
UV
power
intensity
unequalled
in
this
field.
The
darkrooms
offer
any
combination
of
UV
sources,
simultaneously
or
not.
Its
key
features
are:
•
Extra
large
capacity
•
Black
rubber
curtain
for
easy
access
into
the
darkroom
•
White-light
bulb
for
normal
observation
•
UV
absorber
shield
to
protect
the
user
from
UV
light
•
Removable
bottom
panel
for
use
with
a
Vilber
Lourmat
ETX
fluorescent
table
The
CN-6
darkroom
holds
one
or
two
hand-held
UV
lamps...
(VL-6
model)
in
any
of
the
three
following
wavelengths:
254,
365
or
312
nm.
The
darkroom
is
supplied
without
lamps
and
allows
different
lighting
possibilities
according
to
the
user’s
choice.
Its
key
features
are:
•
Large
capacity
•
Black
rubber
curtain
for
easy
access
into
the
darkroom
•
UV
absorber
shield
to
protect
the
user
from
the
UV
light
•
Removable
lamps
that
can
be
used
for
hand-held
applications
Models
|
Tubes
(Watt)
|
Wavelength(nm)
|
Intensity
at
bottom
|
Size
|
VLCN15-LL
|
4
x
15-W
|
365
|
2
000
|
505
x
415
x
280
|
VLCN15-CC
|
4
x
15-W
|
254
|
1
750
|
VLCN15-MM
|
4
x
15-W
|
312
|
2
500
|
VLCN15-LC
|
4
x
15-W
|
365/254
|
1
050/900
|
VLCN15-LM
|
4
x
15-W
|
365/312
|
1
050/1300
|
VLCN15-MC
|
4
x
15-W
|
312/254
|
1
300/900
|
VLCN6
|
Lamps
not
included
|
300
x
280
x
240
|
|
|
Blook LED transilluminator
Ergonomic
fusion-Patented
4°
ergonomic
viewing
angle
(
“Golden
Angle”
)
Optimized
for
use
with
the
nucleic
acid
and
protein
fluorescent
dyes.
•
Blue
light
source
good
for
30,000
hours.
•
No
risk
of
UV
damage
for
high
quality
work
experience.
•
Smart
power-saving
function
-
Automatic
power
shut-off
option
at
5
minutes.
•
Gel-cutting
knife
-
Cut
out
the
target
from
the
gel
for
further
experiment.
BLooK
is
a
remarkable
blue
light
LED
transilluminator
for
the
detection
of
nucleic
acids
or
protein
under
non-UV
conditions.
The
wavelength
of
the
special
blue
LED
lights
is
470
nm
(fig
1),
hence
no
damage
to
your
nucleic
acids
or
protein.
Also,
since
UV
is
not
used,
there
is
no
need
for
any
special
personal
eye
or
skin
protection.
The
blue
LED
lights
are
arranged
under
the
viewing
area
(200
×
120
mm).
An
amber
filter,
on
hinges,
is
lowered
into
position
once
your
gel
is
mounted.
The
stained
gel
is
now
ready
for
viewing.
This
instrument
has
a
specially
designed
ergonomic
4°
angle,
so
users
can
easily
sit
on
a
chair
to
see
the
experiment
results.
However,
BLooK
is
not
suitable
for
ethidium
bromide.
Code
|
Description
|
Unit
Dimensions
|
295
X
215
X
42
cm
|
Gel
veiwing
dimenstions
|
200
X
120
mm
|
LED
source
|
Blue
light
LED
|
LED
life
(hours)
|
>30,000
|
Emission
maxima
|
470
|
|
Code
|
Description
|
Auto
shut-off
(min)
|
5
|
Filter
Type
:
Amber
filter
ideal
for
Novel
Juice,
Novel
Green,
Novel
Green
Plus,
Nimble
Juice
or
Nimble
Juice
RTYPE.
and
for
OnePCR
,
OnePCR
HiFi,
OnePCR
HotStar,
OnePCR
Plus,
OneMARK
B,
OneMARK
100,
|
|
|
|
Face
shield
and
goggle
UV
radiation
is
dangerous
for
unprotected
eyes
and
skin.
Users
must
protect
themselves
against
UV
radiation
by
wearing
glasses
or
face
shields.
The
MP-80
is
recommended
for
the
protection
of
the
eye
and
the
face.
The
MP-800
is
a
face
shield
with
two
lateral
protections
to
cover
the
operator
ears
in
addition
to
his
eyes
and
face.
Comfortable
and
efficient,
the
LP-70
glasses
provide
total
protection
for
the
eyes.
Ordering
codes
:
VLMP800
MP-800
UV
face
shield
with
lateral
protection
VLMP80
MP-80
UV
face
shield
VLLP70
UV
glasses
|
|
The
conversion
screen
converts
the
312
nm
UV
light
into
blue
or
white
light.
The
FC-26.WL
converts
UV
to
white
light
and
is
ideal
for
autoradiographs
or
protein
gels.
The
FC-26.Blue
converts
UV
to
blue
light
(480
nm)
and
it
could
be
used
for
application
such
as
GFP
II,
SYBR
Safe®,
SYBR
Green®
or
SYPRO
Orange®.
Ordering
codes
:
VLFC26-WL
UV/WL
conversion
screen
VLFC26-BLUE
UV/BLUE
conversion
screen
|
|
Replacement
UV
tubes
and
starters
Code
|
Description
|
Length
|
VLT15-M
|
UV
tube,
15
W,
312
nm
|
451
mm
|
VLT15-C
|
UV
tube,
15
W,
254
nm
|
451
mm
|
VLT15-L
|
UV
tube,
15
W,
365
nm
|
451
mm
|
VLT15-WL
|
White-light
tube,
15
W
|
451
mm
|
VLT8-M
|
UV
tube,
8
W,
312
nm
|
302
mm
|
VLT8-C
|
UV
tube,
8
W,
254
nm
|
302
mm
|
VLT8-L
|
UV
tube,
8
W,
365
nm
|
302
mm
|
VLT8-WL
|
White-light
tube,
8
W
|
302
mm
|
|
Code
|
Description
|
Length
|
VLT6-LC
|
UV
tube,
6
W,
365/254
nm
|
226
mm
|
VLT6-C
|
UV
tube,
6
W,
254
nm
|
226
mm
|
VLT6-L
|
UV
tube,
6
W,
365
nm
|
226
mm
|
VLT6-WL
|
White-light
tube,
6
W
|
226
mm
|
VLT4-C
|
UV
tube,
4
W,
254
nm
|
136
mm
|
VLT4-L
|
UV
tube,
4
W,
365
nm
|
136
mm
|
VLST151
|
Starter
for
4...20W
tube
|
|
|
|
|
|
|
|
UV
Crosslinkers
- Three
models:
254,
312
and
365
nm,
each
with
5
UV
tubes
of
8
W. -
Nine
presets
for
time
and
energy
exposures
as
well
as
manual
control
by
the
user
. -
Timer
up
to
999.9
minutes. -
Exposure
ranges:
0...99.99
and
0...9.999
J/cm2. -
Storage
of
the
last
UV
settings
in
a
non-volatile
memory. -
A
photo-feedback
system
automatically
compensates
for
output
variation
and
tube
aging. -
UV-blocking
viewing
window. -
Internal
dimensions
(HxDxW):
15x33x26
cm. -
External
dimensions
(HxDxW):
31x36x35
cm.
|
|
|
|
|
|
|