  STREPTAVIDIN COATED PLATES  for the well-being of your assay

  Streptavidin coated plates are suitable for a wide range of applications, like immuno or nucleic acid hybridization assays.

  The plates are available in several different 96-well formats: 12 & 8 well strips, solid plates or breakable strips enabling use of different instrumentation

  and assay configurations. Also other plate formats are available on request.

  All the plates have high affinity towards biotin and are stable over a wide range of pH, detergent concentration and ionic strength.

  The available plate families differ regarding binding capacity, background, streptavidin leaching and cost.

  For assays suffering from streptavidin leaching we recommend the UniverSA96 plates and for ELISA- type measurements the KaiSA96 plates.

  Anti-mouse coated plates are coated with polyclonal rabbit anti-mouse IgG antibodies.

  Currently the plates are available in 12-strip format, but other plate formats are available on request.

 

  Applications  for Streptavidin Coated Microplates                       

 Streptavidin is a tetrameric protein of approximately 60 kDa in size.

 The streptavidin-biotin interaction is one of the strongest non-covalent bonds in nature.  Streptavidin-coated surfaces serve as a universal binder for immobilization of any

 biotinylated molecule.

 Typically streptavidin plates are used for immobilization of capture antibodies, antigens or

 even small-size biotinylated molecules, which are hard to immobilize directly.

 Unlike proteins directly bound by passive adsorption, biotinylated proteins can be immobilized

 to streptavidin-coated surfaces with a lower risk of denaturation.

 Streptavidin coated plates are widely used in for example competitive immunoassays,  reagents

 excess non-competitive immunoassays and oligonucleotide quantitation.

 

MODELS  

 KaiSA96                                        

 Features:

  Cross-linked streptavidin surface

  High binding capacity

  High uniformity due to the optimized coating process

  Good stability during storage

  Low protein leaching 

 

Specifications:

  Streptavidin coating volume: 200 µl / well

  Biotin binding capacity: > 14 pmol / well

  Plate homogeneity: ~ 3 CV%

  Stability: 2 years at RT or + 4 C° 

 

 

 Plate formats available:

  8 or 12 -well strips

  Solid 96 -well plates

  Breakable modules

    (12 strips of 8 individual wells)

  Additional plate formats available through

    custom services.  

 

 KaiSA96LOW                              

 Features:

  Cross-linked streptavidin surface

  •High binding capacity

  •Low fluorescence background

  •High uniformity due to the optimized coating process

  •Storage at RT or + 4 C

  •Recommended for fluorescence-based assays

 

Specifications:

  Streptavidin coating volume: 200 µl / well

  Biotin binding capacity: > 14 pmol / well

  Plate homogeneity: ~ 3 CV%

  Stability: 2 years at RT or + 4 C° 

 

 

 

 Plate formats available:

  Special yellow polystyrene 12-well strips.

 

 

 

 

 

 

 

 UniverSA96                                

  Features:

  Streptavidin bound covalently onto the surface

  •Lower protein leaching compared to KaiSA96 plates

  •High binding capacity

  •Low background

  •High uniformity due to the optimized coating process

  •Storage at + 4 C°

  •Recommended for ultra-sensitive and/or competitive

    assays

 

Specifications:

  Streptavidin coating volume: 200 µl / well

  Biotin binding capacity: > 14 pmol / well

  Plate homogeneity: ~ 3 CV%

  Real-time stability tests on-going

 

 

 

 

 

 Plate formats available:

  8 or 12 -well strips

  Solid 96 -well plates

  Breakable modules

   (12 strips of 8 individual wells)

  Additional plate formats available

    through custom services.

 

 

 

 

 Anti-mouse                              

Features:

  Polyclonal rabbit anti-mouse immunoglobulin

    coated surface

  Passively coated

  •Saturated for low non-specific binding

  •High uniformity

  •Storage at +4C

  •Recommended applications include bioaffinity

    assays and screening of mouse antibody producing

    cell lines

 

Specifications:

  Antibody coating volume: 200 µl / well

  •Coated with 1 µg of antibody

  •Stability: 2 years at + 4 C

 

 

 

 

 

 

 

 Plate formats available:

  12-well strip plates

  Additional plate formats available through

    custom services

  Anti-mouse LOW plates for

    fluorescence-based applications available

    through custom services

 

 

 

 

 

 Custom services                     

  Were you unable to find what your assay needs from our product offering? Kaivogen also has a custom service to fulfil your assay’s demands

  regarding coating of microplates, lanthanide chelates or buffers. Let us help you to make your assay happy!

  

  Custom coating: Should you need a coating other than streptavidin or anti-mouse on your plate, Kaivogen provides custom plate coating service.

  We can perform the coating according to your protocol or do a process optimization to guarantee optimal performance of your plates.

  All custom coatings take place in our validated production facilities and are made by ISO 9001 and/or ISO 13485 certified procedures.

  Final product is not under the certification. The service is also available in 384-well plate format.

  

  Tailor made buffers: Save time and outsource your buffer production! For common buffers we have a stock of standard laboratory reagents but

  we can also do small scale buffer production according to your recipe. Ask for Kaivogen custom service and benefit from our experience!

  

  Kaivogen can provide all the components you need for the well-being of your assay!  

 

      REFERENCES  

Streptavidin - A Versatile Binding Protein for Solid-Phase Immunoassays

Data Sheet 보기

SELECTION AND SCREENING OF SINGLE CHAIN VARIABLE FRAGMENT ANTIBODIES AGAINST HUMAN PARECHOVIRUS 1

Data Sheet 보기

The selection performance of an antibody library displayed on filamentous phage coat proteins p9, p3 and truncated p3

Data Sheet 보기

The effects of acute hyperinsulinemia on bone metabolism

Data Sheet 보기

Two ScFv antibody libraries derived from identical VL–VH framework with different binding site designs display

distinct binding profiles

Data Sheet 보기

Escherichia coli–expressed near full length HIV-1 envelope glycoprotein is a highly sensitive and specific

diagnostic antigen

Data Sheet 보기

A Common Prostate Cancer Risk Variant 5′ of Microseminoprotein-β (MSMB) Is a Strong Predictor of

Circulating β-Microseminoprotein (MSP) Levels in Multiple Populations

Data Sheet 보기

Troponin-Specific Autoantibody Interference in Different Cardiac Troponin I Assay Configurations

Data Sheet 보기

Synthetic single-framework antibody library integrated with rapid affinity maturation by VL shuffling

Data Sheet 보기

Epidemiology of two human protoparvoviruses, bufavirus and tusavirus

Data Sheet 보기

Epitope Specificity and IgG Subclass Distribution of Autoantibodies to Cardiac Troponin

Data Sheet 보기

Europium Nanoparticle-Based High Performing Immunoassay for the Screening of Treponemal Antibodies

Data Sheet 보기

High Gradient Magnetic Separation of Upconverting Lanthanide Nanophosphors Based on Their Intrinsic Paramagnetism

Data Sheet 보기

Recombinant antibodies for specific detection of clostridial [Fe-Fe] hydrogenases

Data Sheet 보기

NANOPARTICLE-ASSISTED IMMUNOASSAYS FOR POINT-OF-CARE TESTING – With Specific Interest in Minimally

Interference-Prone Assays for Cardiac Troponin I

Data Sheet 보기

Immuno-based detection of extracellular vesicles in urine as diagnostic marker for prostate cancer

Data Sheet 보기

 

bar002.png