Measurement principle
Milk checker is handy type instrument for cows to measure the electrical conductivity of milk in quarters of udder and to detect mastitis.
When inflammation or other mammary disorders occurs, plasma constituents may exudate and cause changes in concentration of electrolytes
contained in cow milk such as Na+, CL-, etc. A rise in sodium and chloride content results in increased electrical conductivity in the milk.
Milk Checker is based on this principle and can detect abnormalities in the udders quickly and accurately by measuring electrical
conductivity of milk.
Advantages
•
Fast and reliable
An innovative technology, Milk Checker is more reliable than other methods of mastitis detection.
Unlike the complicated California Mastitis Test, which is subjective and requires mixing the milk with a solution, Milk Checker numerically
displays results on digital display, with decimal precision, thus saving time and money.
•
Monitors your herd’s health
Milk Checker is an important in the management of herd. By using Milk Checker regularly throughout the lactation period, one can easily
identify the infected cattle and separate them from the rest of herd.
In addition, Milk Checker can also be used to determine the efficiency of antibiotic
treatment.
•
Prevents outbreaks of clinical mastitis
Every year, mastitis outbreaks result in substantial losses for dairy farmers. Therefore, prevention is imperative. It is be able to detect
infection at a preliminary stage, when it is still imperceptible.
Thus, you avoid the high costs of veterinary treatment, antibiotics, and discarding milk and cattle, etc.
Quality
Milk Checker is a compliant device to Special disease medical guidelines by Mutual Aid Association of Veterinary Japan, as applicable
electrical conductivity might be risk of mastitis infection in the
quarter.
Therefore, Milk Checker is favored mastitis detector in most countries with high quality control of milk such as Japan, Australia, and New Zealand.
Absolute Conductivity
:
|
6.2mS / cm or more |
Abnormal milk |
The guideline of electrical conductivity for confirmation
on mastitisby Mutual Aid Association of Veterinary Japan
|
Differential Conductivity
: |
0.5mS / cm or more |
Infected |
Specification
Measuring Method: |
Measurement of electrical conductivity
|
Calculation: |
Differential E.C. is calculated by microcomputer and automatically calibration. |
Display: |
Backlight LCD |
Measurement Range: |
0 - 13mS/cm |
Accuracy: |
3% ± 1 digit |
Automatic Temperature Compensation: |
+3 - 40℃ (compensated at +25℃) |
Power Source: |
Dry cell battery AA x 2 pcs. |
Power Consumption: |
140 mA (measuring and backlight on) |
Dimensions: |
91(w) × 149.5(H) × 118(D)mm |
Weight: |
320 g |
Data Communication: |
Bluetooth® |
Real Time Clock: |
IC module |
EEPROM: |
Storage 500 data in device |
Comparative Table
Milk
Checker
vs CMT
| | |
Can the test be done quickly (within seconds)? | X | ✓ |
Are the results reliable? | X | ✓ |
Is the interpretation of data done by computer, with decimal precision? | X | ✓ |
Can the test be done in an environment with low visibility? | X | ✓ |
Does it have a digital display? | X | ✓ |
Can the measurement data save? | X | ✓ |
Is it possible to control data management by PC? | X | ✓ |
Does not require use of chemical reagent? | X | ✓ |
Does it have temperature sensor? | X | ✓ |
|