MFG-1000
|
IMPLEMENTA
|
|
전자기장 발생기 ( Electro MAGNETIC FIELD GENERATOR ) for Bio- medical research.
|
PCR vial 또는 microscope slide 에 high-frequency magnetic field 제공.
|
Biochemical
and medical
fields에서
in vitro magnetic field 조건의 실험이 필요한 샘플
(Magnetic nanoparticles, Tissues, cells, bacteria, viruses, biological fluids( blood..)에 적용.
|
Generating
fixed high
frequency
(1
MHz) and
a variable
(continuous
or pulsed)
homogeneous
magnetic
field (max
5
mT).in a
temperature
controlled
compartment
in the device
|
The
desired
field
properties
(field strength,
constant/pulsed
mode, and
field exposure
time)
are set
using
the keyboard
|
|
|
Applications: Application
Note 보기 :
|
Medical
applications of static
magnetic fields (generated
by magnets) were sug-gested
already 4000 years ago
by Aristotle
and Plato. During
the last decades, a
variety of functionalized
superparamagnetic nanoparticles,
capable of interacting
with cells
and other
biological
substances, have been
developed. Such nanopar-ticles
in combination with
alternating magnetic
fields
(generated by
coils) has at-tracted
much attention in medical
and scientific research
applications. These
ap-plications involve
areas such as Hyperthermia,
Cell-membrane receptor
targeting, Cell and
bacteria lysis.
Typical research applications may involve the use of magnetic nanoparticles, tissues, cells, bacteria, viruses, and biological fluids.
|
|
Technical
data
Magnetic flux density
adjustable range
|
0 - 50 Gauss
in 0,1 mT steps
|
Magnetic Field strength adjustable range
|
|
Volume of homogeneous magnetic field
|
|
Field activation time setting range
|
|
Field activation in pulsed
mode duty cycle
|
ON (1 - 255 s),
OFF (1 - 255 s)
|
Sample container regulation temperature
|
|
*
The generated magnetic flux density has been calibrated against an external reference coil at the factory. The displayed value of the generated magnetic
flux density is calculated from real-time measurments of the coil current. |
|
Order information |
Art no |
Product |
No |
2102-01 |
MFG-1000 package - Including 1 MFG-1000 instrument, 1 power supply/cord, 1 pcs Sample container PCR VIAL and 1 operator manual |
1 |
2102-03 |
Sample container PCR VIAL (0.2 mL) |
100 |
2102-04 |
Sample container MICROSCOPE SLIDE |
1 |
|
• Ferromagnetic nanoparticles 제공 :
for antibodies, enzymes and other proteins application examples - Magnetic enzyme: Glucose oxidase, Peroxidase,
ß-Galactosidase, Alkaline phosphatase, ProteinA,G
- Antibodies (polyclonal) : Anti-human IgG, Anti-human IgM (µ), Anti-Bovine IgG, Anti-Goat IgG,
Anti- Monkey IgG, Anti-Pig IgG - Magnetic protein: Avidin , Albumine (bovine)(human).
|
|
|
|
|